AM16/32 Relay Analog Multiplexer 1. Function The primary function of the AM16/32 Multiplexer is to increase the number of sensors that can be measured by a CR23X, CR10(X), 21X, or CR7 datalogger. The AM16/32 is positioned between the sensors and the datalogger. The AM16/32 is a replacement for CSI’s AM and AM32 models. Mechanical. AM16/32B Relay Analog Multiplexer. For a discussion of single-ended versus differential analog. measurements, please consult the Measurement section of your datalogger manual. NOTE. As purchased, the AM16/32B is intended for use in indoor, non-condensing environments. An enclosure is required for field or high humidity use. In. · The AM16/32B either multiplexes 16 groups of four lines (a total of 64 lines) through four common (COM) terminals. Alternatively, a manual switch setting allows the AM16/32B to multiplex 32 groups of two lines (also a total of 64 lines) through two COM www.doorway.rum Clock Pulse Width: 1 ms.
AM16/32B Relay Multiplexer 6 When the AM16/32 multiplexer is added as a device, a new AM16/32 tab will appear at the bottom of the Available Sensors and Devices pane. With the AM16/32 tab selected, select the Sensors Temperature subfolder. Doubleclick on Temperature Probe (4-wire). In the resulting window, enter the. Campbell Multiplexer AM16/32B Instruction manual (44 pages) 5. Campbell AM Campbell Multiplexer AM16 Instruction manual (46 pages, Mb) 6. Campbell AM32A. Campbell Multiplexer AM32A Instruction manual (46 pages, Mb) 7. Campbell AM25T. View online Product manual for Campbell AM16/32B Multiplexer or simply click Download button to examine the Campbell AM16/32B guidelines offline on your desktop or laptop computer.
AM16/32B Relay Analog Multiplexer. For a discussion of single-ended versus differential analog. measurements, please consult the Measurement section of your datalogger manual. NOTE. As purchased, the AM16/32B is intended for use in indoor, non-condensing environments. An enclosure is required for field or high humidity use. In. Alternatively, a manual switch setting allows the AM16/32B to multiplex 32 groups of two lines (also a total of 64 lines) through two COM terminals. A cable connects the common terminals to data logger analog inputs, excitation channels, or ground as required by the sensor. The data logger controls the multiplexer using two control ports, or one control port and one excitation channel. Electrical Surge Protection. AM16/32 Relay Analog Multiplexer 1. Function The primary function of the AM16/32 Multiplexer is to increase the number of sensors that can be measured by a CR23X, CR10(X), 21X, or CR7 datalogger. The AM16/32 is positioned between the sensors and the datalogger. The AM16/32 is a replacement for CSI’s AM and AM32 models. Mechanical.
0コメント